Intercom Manual

PANPHONE IP CSIP V6

Installation, configuration and commissioning manual for the PANPHONE CSIP V6 with firmware 6.0.

Document details

Device PANPHONE IP CSIP V6
Identification shown by the device CSIP H6 - V 6.0
Firmware covered6.0
Manual CSIP V6 - 6.0 - EN (translated from ES)
Type Installation and configuration technical manual
Queries

For installation or configuration questions, see the contact and support section at the end of this manual.
Contact support

Warning and declaration of conformity

This document refers to the device PANPHONE IP CSIP V6.

For questions about installation, configuration or operation, see the Contact and support section.

Use of the document. Reproduction of this manual in whole or in part without authorization is prohibited.

The manufacturer reserves the right to make hardware or software modifications to the device described in this document. Available functions may vary depending on firmware version, activated licenses, installed modules and device configuration.

General index

1. Introduction

5 subpoints ▼

General description, features, preliminary information and CSBOX formats.

4. SIP accounts

4 subpoints ▼

SIP accounts, PBX registration and allowlist.

6. Multimedia

5 subpoints ▼

Audio, video, RTSP and voice prompt settings.

Activation of modules and extra functions.

10. Tools

4 subpoints ▼

Test calls, restart, updates, API and Cloud.

11. Users

1 subpoint ▼

User, language and security management.

Common questions and diagnosis.

16. Contact and support

1 subpoint ▼

Technical support channels.

1. Introduction

Welcome to the PANPHONE IP CSIP V6 manual. This equipment is part of a line of communication and access control systems aimed at industrial environments, offices, multi-family buildings and facilities where it is necessary to manage calls and door access safely.

1.1 Overview

The PANPHONE CSIP V6 is an intelligent, hands-free IP intercom that can be connected as a SIP extension of an IP telephone PBX (IP PBX), to a SIP trunk or to another terminal via direct IP call. It can work on a local network or in remote scenarios, depending on the network and communications configuration available at the installation.

The equipment has relays with voltage-free contacts to activate doors, barriers or other external devices, such as lights, sirens or auxiliary systems. Activation can be done during communication, using DTMF codes from an authorized telephone or through access control systems configured on the board.

Programming is done from a built-in web interface of the device. To access it, use a compatible browser from a computer connected to the same Ethernet network or through the access path established by the installer.

The web interface organizes the configuration in the sections Home, SIP Accounts, Connectivity, Multimedia, Relays, Keypad/Pushbutton, Modules and licenses, Tools and Users.

1.2 Main Features

SIP communication

Up to five independent SIP accounts with the main audio codecs, communication via IP PBX, SIP trunk or direct point-to-point call over IP.

Audio and call

Full-duplex audio, auto-answer for incoming calls, signaling tones, pre-recorded audio, echo cancellation and noise reduction.

Sound settings

Independent control of speaker volume and microphone sensitivity, with remote audio test from the web interface.

Video and multimedia

Possibility of video calls with optional camera, image adjustments, recordings, RTSP streaming, LCD screen and voice prompt language selection.

Connectivity

Ethernet connection and wireless communication via WiFi or optional 4G/LTE, as well as network utilities such as Ping, SMTP, SNMP and VPN.

Relay activation

Activation of relays from extensions or telephones that support DTMF, with voltage-free contacts for doors or other external devices.

Access control

Access system using PIN code, RFID cards, QR codes, schedules and access assignment to specific relays.

Histories and logs

History of actions or events, access control history and VoIP traffic log for review and technical diagnosis.

Web interface

Complete device configuration through internal web server, with differentiated menus for network, SIP, multimedia, access, tools and users.

Calls from the web

Make test calls to extension or IP address directly from the configuration interface.

Keypad and push button

Configurable keys, dialing modes, manual dial length, access PIN length and status LED settings.

Modules and integrations

Support RS485, API, Modbus, SNMP, OPTO board, third relay, WiFi, 4G/LTE, video, RFID and QR depending on installed hardware, license and configuration.

1.3 Technical characteristics

1.4 Data required before configuring

Before starting the configuration, the installer must have the network data, authorized access credentials, SIP information and relay connection diagram. Technical parameters should not be modified without knowing their effect on the installation.

Necessary information What is it used for?
IP address or device access methodAllows you to enter the web panel to perform configuration.
Authorized username and passwordAllow access to the web interface. Keep them secure and replace factory credentials during commissioning.
SIP dataExtension, user, password, server, port, transport and registration type so that the panel can call or register in the PBX.
Network dataDHCP or fixed IP, mask, gateway, DNS and VLAN if applicable.
Relays and accessesIdentification of each door, barrier, lock or automation connected to each relay.
Installed modules and licensesCamera, RFID, QR, RS485, OPTO, WiFi, 4G/LTE, SNMP, API or other modules available depending on the equipment supplied.

Important. Access credentials to the equipment must be guarded by authorized personnel. They should not be included in public documentation or shared with unauthorized users.

1.5 CSBOX Formats

The equipment is also available in CSBOX format (plastic or metal box) for installations that do not require the usual front panel. The dimensions of the case are 125 x 93 x 52 (or 42) mm.

Plastic or Metal CSBOX (125 x 93 x 52 or 42 mm).
Model Description
CSBOX-P-IPEnhanced Full Duplex Audio IP-SIP Intercom PCB assembly with Gray plastic case. Speaker output power up to 1W.(*)
CSBOX-P-IP-10WEnhanced Full Duplex Audio IP-SIP Intercom PCB assembly with Gray plastic case. 10W amplifier. Speaker output power up to 10W.(*)
CSBOX-P-IP-OPTOIP-SIP Intercom PCB assembly Enhanced Full Duplex Audio with Gray plastic case + OPTO card. Speaker output power up to 1W.(*)
CSBOX-P-IP-10W-OPTOIP-SIP Intercom PCB assembly Enhanced Full Duplex Audio with Gray plastic case + OPTO card. 10W amplifier. Speaker output power up to 10W.(*)
CSBOX-P-IP-10W-BMIP-SIP Intercom PCB assembly Enhanced Full Duplex Audio with Gray plastic case + MAGNETIC LOOP. 10W amplifier. Speaker output power up to 10W.(*)
CSBOX-P-IP-10W-OPTO-4GIP-SIP Intercom PCB assembly Enhanced Full Duplex Audio with Gray plastic case + extra 4G Module. 10W amplifier. Speaker output power up to 10W.(*)
CSBOX-P-IP-10W-CAMIP-SIP Intercom PCB assembly Enhanced Full Duplex Audio with Gray Plastic Case + USB Camera. 10W amplifier. Speaker output power up to 10W.(*)
CSBOX-M-IPImproved Full Duplex Audio IP-SIP Intercom PCB assembly with Aluminum metal case. Speaker output power up to 1W.(*)
CSBOX-M-IP-10WImproved Full Duplex Audio IP-SIP Intercom PCB assembly with Aluminum metal case. 10W amplifier. Speaker output power up to 10W.(*)

2. Installation, assembly and connection

The installation of the PANPHONE IP CSIP V6 must be carried out according to the supplied model, the mounting accessory and the installation electrical diagram. Before fixing or powering the equipment, check the wiring route, the location of the connectors, the available power and the destination of each relay.

2.1 Installation models

The equipment can be supplied in different installation formats. The assembly procedure depends on the model purchased and the accessory used.

PANPHONE IP CSIP V6 mounting models and references
Models and assembly references of the PANPHONE IP CSIP V6.

2.2 Necessary material

For the basic mechanical installation, at least the following material is required:

2.3 Surface mounting

  1. Hold the base or rear cover in its final position.
  2. Mark the fixing points on the wall.
  3. Drill the marked points and place the plugs.
  4. Route the necessary wiring before closing the assembly.
  5. Fix the base to the wall with the corresponding screws.
  6. Install the front panel of the intercom.
  7. Tighten the security screw located at the bottom of the device.

2.4 Flush mounting

For the flush-mounted model, prepare an opening of approximately 182 x 92mm with a depth of 30mm. Before making the hole, confirm the dimensions of the supplied accessory and leave enough space for the wiring to pass through.

2.5 Identifying internal connections

The board photograph supplied for this review is marked “CSIP V6.1”, but its front view does not establish the function and numbering of every terminal. Before wiring, use the markings and electrical diagram for the physical revision supplied. “CSIP H6 — V 6.0” is the panel string; it does not, by itself, identify the board revision.

2.6 Power supply and relay connection

The installation may use Ethernet PoE or an external supply compatible with the board supplied. Wire relay contacts according to the diagram for that board and the connected device. Do not apply power to a terminal or connect a lock based only on a photograph or on the numbering of another revision.

Before wiring. Confirm polarity, voltage, relay ratings and the function of each terminal on the physical board with the technical owner. The V6.1 revision terminal diagram is awaiting validation for this edition.

2.7 NO/NC relay contact configuration

The relay contacts can be configured as NO (normally open) or NC (normally closed) using the corresponding jumpers on the board. This configuration must be defined according to the type of lock, door opener, barrier or connected automation.

Caution. Do not exceed the maximum capacity allowed by the relay contacts. If in doubt, use an intermediate relay or consult the installation electrical diagram.

2.8 Equipment configuration jumpers

The Home panel reports the state of three jumpers. That reading does not establish what each position does on the physical revision supplied. Do not add or remove jumpers to change the network or reset the device without the approved diagram for that board and the service procedure.

2.9 Access recovery

If the routine panel password is forgotten, use the individual recovery credential supplied for that same device by the authorised administrator. If the current IP is unknown or the credential does not grant access, ask the technical owner for the procedure specific to the physical revision. Do not apply a jumper sequence from another revision without verifying it.

2.10 Checks before powering up the equipment

Security. The assembly, power supply and connection operations of locks or automation must be carried out by qualified personnel. Do not handle wiring while the equipment is powered.

3. Programming and first access

The configuration of the PANPHONE IP CSIP V6 is done from its internal web interface. To access it, the computer must be on the same network as the device, or have a network route to the address specified by the installer. This first part explains access to the panel, the login screen, the main menu and the Home screen.

3.1 Browser access

Use a supported browser, preferably Chrome or Microsoft Edge. In the address bar, enter the device's IP followed by the web access port.

Note. If the current IP is unknown or the routine password has been forgotten, see the safe recovery options in section 2.9.

3.2 Login screen

When accessing the device's web address, the login screen is displayed. From this screen you enter the username, password and interface language.

Field Description
UserUsername authorized to access the web panel.
PasswordPassword associated with the user. It must be kept safe and changed after startup if a default key is maintained.
LanguageLanguage in which the web interface will be displayed. The panel language selection does not necessarily replace the language of the audio voice prompts.
SendValidate the data entered and open the configuration panel.
ResetClears the fields on the login screen.
PANPHONE IP CSIP V6 login screen
Login screen.

3.3 Access and recovery credentials

The day-to-day password grants access to this device's web panel. The device may prompt you to change it after the first login. The device-specific recovery credential supplied by the administrator still allows access to this same device if the new password is forgotten; it is not a shared password for other devices.

Safekeeping. Store the individual recovery credential in the installation's approved password manager, linked to the device identifier. Do not publish it in this manual or include it in screenshots or support requests. If exposure is suspected, ask the administrator for the applicable replacement or revocation procedure.

3.4 Main menu

Once the access data has been entered, the panel displays a side menu with the main configuration categories. This menu remains available during navigation and allows you to jump between sections.

3.5 Home Screen

6.0 Home screen. The device IP, MAC and event details are concealed.
6.0 Home screen. The device IP, MAC and event details are concealed.
Reference Screen

General condition of the equipment

The Home screen shows the device identification, date and time, network, jumpers, relays and events. The device reviewed also shows a Cloud indicator beside the version. Check these values on your own device; another installation's values are not a reference.

The Home screen is the first check view. It is not used to program complex parameters; It is used to verify the status of the equipment before continuing with the configuration.

Data displayed Utility
Current versionThe updates screen shows “CSIP H6 — V 6.0” on the device reviewed. The 6.0 part identifies firmware; do not infer the processor from this string.
System date and timeIt must be correct for schedules, events, logs and temporary access to work properly.
UptimeIndicates how long the device has been running since the last boot.
Processor temperatureHelps detect abnormal operating or ventilation conditions.
IP and MAC addressIdentifies the active network connection of the device.
JumpersShows the status of the configuration jumpers read during boot.
Relay statusIndicates whether each relay appears active or deactivated.
Latest eventsSummarizes recent events, such as SIP registrations, calls, accesses, or logins.

Initial check. Before continuing, verify that the version is as expected, the time is correct, the IP corresponds to the installation and the relays appear idle unless there is a test or maneuver in progress.

3.6 First commissioning summary

Use this sequence as a quick guide for a basic installation. Each step refers to later sections of the manual when it requires more detailed configuration.

Step Action Check
1Assemble the equipment and check the connections.The equipment is fixed, without mechanical stress on cables and with identified relays.
2Power via PoE or approved external power supply.The board boots and allows access to the web panel.
3Access the panel from the browser.The login screen is displayed.
4Log in with authorized credentials and change the password if applicable.Access is protected before the installation is delivered.
5Review Home, date/time, network, jumpers, relays and events.No abnormal states appear before configuring calls or openings.
6Configure necessary network and connectivity.The IP, gateway, DNS, WiFi, 4G/LTE or VPN match the installation.
7Configure the SIP account or direct call.Confirm that the account registers or that the point-to-point call works.
8Configure relays, PIN, RFID, QR or schedules if applicable.Each credential activates only the intended door or output.
9Make a test call and opening test.Audio, call, DTMF and relays work correctly.
10Log out and document the delivered configuration.Only the installed, activated and tested functions are noted.

4. SIP accounts

The SIP Accounts section allows you to configure PANPHONE IP CSIP V6 calls. From this section, SIP accounts, PBX registration or direct IP calls, the allowlist of incoming calls and general communication parameters are managed.

PBX settings SIP extension or username, password, server, port, transport and supported codecs.
Call type Select PBX to register with a telephone system, or IP for direct point-to-point calls.
Network used by SIP Cable, WiFi, 4G/LTE or VPN depending on installed hardware and facility network.

4.1 Account overview

SIP account list; configured extensions are concealed.
SIP account list; configured extensions are concealed.
Reference Screen

Status of available accounts

It is used to see the five SIP accounts on the device, know if they are registered or inactive and enter Configure to edit only the corresponding account.

Item What to view or select Note for configuration
SIP account 1 to 5Select the account to use for installation.Configure only the necessary accounts. Unused accounts should be left inactive.
RegisteredThe account appears correctly connected to the PBX or SIP service.This is the expected state after saving and applying a PBX account with network available.
InactiveThe account is disabled or does not have valid settings.If that account should work, open Configure and check username, password, server and network.
Name / Ext.Should display the ID assigned to that account.It is best to use the actual extension or a recognizable name of the installation.
ConfigurePress to edit the corresponding account.Do not change multiple accounts at once; Set up and test one before moving on to the next.

4.2 Setting up a SIP account

SIP account form with identifying fields left blank.
SIP account form with identifying fields left blank.
Reference Screen

Registration and communication data

The data provided by the PBX or the network administrator is entered here. If any key field does not match, the account will not register or the calls will not work correctly.

Field What to enter How to decide
Enable accountEnabled if that account is to be used.Must be checked to register or call from that account. Disable it if not used.
Registration in PBX or P2P (IP)PBX if there is a PBX. IP if you called directly to an IP address.PBX is common in installations with extensions. IP is used in point-to-point scenarios.
NameIdentification name of the account.Use a clear name to identify the device: main entrance, garage door, reception, etc.
User / Ext.SIP user or assigned extension.It must match exactly the data in the PBX.
PasswordSIP account password.Copy it without spaces. If registration fails, check capitalization, symbols, and length.
PBX domainDomain or IP of the PBX, if required.It can be left empty only if the PBX does not request it.
SIP Server 1IP or domain of the main SIP server and its port.The usual port is 5060, unless otherwise configured.
SIP Server 2Secondary server, if any.Use only if the installation has a backup SIP server.
TransportUDP, TCP or available option indicated by the PBX.UDP is usually common; Always respect the PBX configuration.
Audio codecPreferred codec order for the call.Select codecs compatible with the PBX. The equipment allows you to prioritize several codecs.
Video codecCodec supported by the video system, if used.Only affects devices with a camera or video call; on devices without video it is not a critical setting.
Re-registration timeSIP registration renewal time.Keep the value indicated by the PBX or the default value if there is no specific requirement.
Registration intervalPercentage of registration time returned by the PBX.Do not change it unless technically indicated.

Recommendation. Set up one account at a time and check your registration before modifying another. If the account does not register, check username, password, server, port, transport, network and connectivity to the PBX.

4.3 Allowlist

SIP allow list. The address shown is an example.
SIP allow list. The address shown is an example.
Reference Screen

Incoming call control

Allows you to decide which SIP origins can call the board. It is especially useful when the device is on a network where unwanted calls may exist.

Field What to enter When to use it
Allow allSelect this option if the panel should accept any incoming calls.Useful in closed and controlled networks, when the PBX already filters the origins.
Block allSelect this option to reject calls by default.Recommended when only specific extensions or sources should be able to call.
Sender 1 to 10SIP address authorized or blocked.Use one line for each source you want to control.
Allow/DenyAction applied to the entered sender.Allow authorizes that origin; Deny blocks it.
Formatsip:user@address, for example sip:<user>@<server-address>.Use the SIP address format expected by your PBX.

4.4 SIP Options

Reference Screen

General communication settings

These parameters affect all SIP calls: network adapter, maximum duration, auto answer, and audio/video port range.

Field What to enter Note / usual value
Network adapter for SIPSelect cable, WiFi, 4G or VPN depending on the network output the board should use.If an option appears as unavailable, the device does not detect that module or connection.
Maximum communication timeMaximum duration allowed for each call.The display allows 0 to 7200 seconds. Use a reasonable limit to avoid open calls indefinitely.
Local SIP portLocal SIP signaling port.5060 is the usual value. Change it only if the network or PBX requires it.
Auto-answerManual, automatic or automatic after 1, 2 or 3 rings.Automatic responds without intervention. Manual requires physical or user action depending on installation.
Start RTP portFirst port in the range used for audio/video.Must be allowed on the network and not conflict with other services.
RTP port endLast port in the range used for audio/video.It must be higher than the initial port and be within the range allowed by the screen.

Caution. SIP/RTP ports and network adapter directly affect how calls work. Do not change these parameters without knowing the configuration of the PBX and the network.

5. Connectivity

The Connectivity section groups the device's network configuration and associated tools: wired network, WiFi or 4G/LTE modules when installed, diagnostic utilities, mail sending, SNMP and VPN connection.

Network data IP address, mask, gateway, DNS, VLAN and DHCP/static criteria.
External services Mail server, recipients, SNMP, trap servers and VPN data if used.
Installed modules WiFi, 4G/LTE and VPN should only be configured when the equipment and installation support it.

5.1 Wired network

Wired network settings. IP, MAC, gateway and DNS values are concealed.
Wired network settings. IP, MAC, gateway and DNS values are concealed.
Reference Screen

Ethernet configuration and network logs

This screen defines the wired network address of the device. It is the main point to leave the board accessible on the customer network and to activate diagnostic logs when necessary.

Field What to enter How to decide
Current IP addressValue displayed by the device.Used to confirm which IP is being accessed at that moment.
MAC AddressPhysical identifier of the network interface.Useful for DHCP reservations, network inventory or filtering on switches/routers.
DHCPOn if the network assigns IP automatically. Off if a fixed IP is configured.For final installations, a fixed IP or documented DHCP reservation is usually recommended.
Static IP addressIP that the board will have when DHCP is disabled.It must belong to the client's network and not be used by another device.
NetmaskMask corresponding to the local network.Must match the installation address.
GatewayIP address of the router that provides access to other networks.Necessary for communication outside the local network, remote SIP, mail, VPN or external services.
DNS ServersPrimary and secondary DNS.Required if domains are used instead of IP addresses.
VLAN IDVLAN identifier if the network requires it. Value 0 indicates no VLAN.It should only be modified if the switch and the client network work with VLANs.
Play IP at startupActivated if you want the device to announce the IP when starting up.Can help with startup or maintenance when the IP is not known.
VOIP SIP LogEnabled for SIP diagnostics only.Use the port indicated by the screen and disable it when the test is finished if not necessary.
Event logEnabled if equipment events need to be logged.Allows you to review operating information from the viewing or download options.

Important. Before changing the IP, confirm that the new address, mask, and gateway are correct. If an IP is saved outside the network, web access may be lost. In that case, consult the safe options in section 2.9 and the technical owner.

5.2 WiFi and 4G/LTE

WiFi tab; no devices are connected in this capture.
WiFi tab; no devices are connected in this capture.
4G/LTE tab; no devices are connected in this capture.
4G/LTE tab; no devices are connected in this capture.
Reference screens

Configuring wireless modules

The WiFi and 4G/LTE tabs allow you to configure the wireless connections when the equipment includes the corresponding module. If a tab indicates that there is no device connected, that connection should not be used for the installation.

Reference Screen

4G/LTE Module

When the 4G/LTE module is available, this screen allows you to review the mobile network status and enter SIM and operator parameters. It should only be configured if the board includes the module and the installation uses a mobile connection.

Screen What to check Interpretation
WiFiRegistration status, SSID, key, security type, MAC address, DHCP, static IP, mask, gateway and DNS.Configure WiFi only if the module is installed and the wireless network has sufficient coverage at the equipment location.
StatusIndicates whether the device is registered/connected to the WiFi network.If Not Registered appears, check SSID, password, security and coverage.
SSIDName of the WiFi network to which the device will connect.It must be written exactly the same as on the access point. The Search for Networks button helps locate available networks.
Password and securityNetwork password and security mode, for example WPA2.Must match the actual configuration of the router or access point.
DHCP
OnOff
On obtains IP automatically. Off allows you to enter static IP, mask, gateway and DNS.
Static IP Address / Mask / Gateway / DNSNetwork parameters used when DHCP is Off.They must belong to the client's WiFi network and not duplicate another existing IP.
4G/LTEMobile network status, signal level, IMEI, PIN, APN, username and password.Configure this data only with a valid SIM and the parameters provided by the operator.
Network IDIndicates whether the mobile module is registered or requires PIN review.If prompted to check PIN, check the SIM PIN before continuing.
Network Type / LevelShows the available coverage using signal bars.If the signal is low, check the antenna, location or operator coverage.
IMEIUnique identifier of the mobile module.It is used for support or registration of the service, it should not be modified.
PINSIM card PIN, if the SIM requires it.Must be entered exactly. An incorrect PIN can block the SIM.
APN / User / PasswordAccess data to the operator's mobile network.Fill them in only with the official data of the operator or the client.
SIP AdapterWhen a module exists, also check the adapter selected in SIP Options.The SIP call must go out through the actually available network: cable, WiFi, 4G/LTE or VPN.

5.3 Network Utilities

Reference Screen

Gateway and PING test

This screen allows you to select the network adapter and launch a connectivity test towards a specific address. It is useful to check if the equipment reaches the PBX, router, SIP server or an external domain.

Network utilities and PING test screen.
Network utilities: gateway and PING test. The result depends on the network and destination.
Field What to enter What is it for?
GatewayGateway associated with the selected adapter.Allows you to check or change the network interface used by the device.
Network adapterCable or other adapter available.Select the link you want to test.
AddressTest destination IP or domain.Use the IP of the PBX, the router or a test domain depending on what you want to verify.
Perform testRun the PING test.The result helps to know if there is connectivity to the indicated destination.
Result areaResult returned by the test.If there is no response, check IP, mask, gateway, DNS, cabling or network rules.

5.4 SMTP

Reference Screen

Sending email from the device

The SMTP setting allows the device to send warning or test emails. It must be filled in with real data from the mail server to be used.

SMTP settings screen with example values.
SMTP settings. The values shown are examples; use those provided by the email administrator.
Field What to enter How to decide
RecipientEmail that will receive the notifications or test messages.It must be a valid address and reviewed by the customer or maintenance.
SenderEmail from which the messages will come.Must be allowed by the SMTP server used.
Use serverInternal or external, depending on the installation's mail server.Use external when the client provides its own SMTP server.
Mail server (SMTP)Domain or SMTP server IP and port.The port depends on the server. The screen shows port 25 as an example of configuration.
UserSMTP authentication user if required by the server.It must match the configured email account.
PasswordSMTP account key.Enter only in facilities where mail delivery is approved and documented.
SecuritySecurity mode available in the dropdown.Select the value required by the mail server.
Send test emailSend an email to verify the configuration.This should be tested before the installation is delivered if mail notices are to be used.

5.5 SNMP

Reference Screen

SNMP monitoring and traps

SNMP allows the equipment to be integrated into supervision systems. It should only be activated when the client has a monitoring platform and provides the necessary parameters.

SNMP settings screen with illustrative values.
SNMP settings. The values shown are illustrative; agree on the community and servers with the administrator.
Field What to enter When to use it
SNMP StatusCurrent status of the SNMP service.Should be checked before documenting active monitoring.
Sending trapsOn if the device should send traps; Off if not used.Enable traps only if servers are ready to receive them.
Server 1 to 3IP or name of the monitoring servers.Use the servers provided by the customer or network administrator.
CommunitySNMP community string.Must match the SNMP platform configuration.
NameIdentification name of the equipment.Use a name that allows you to recognize the location or function of the board.
DescriptionDevice description.Helps identify it in the monitoring tool.
LocationPhysical or logical location of the equipment.Identify the location clearly for maintenance: entrance, door, building, floor, etc.
ContactEmail or responsible contact.Use a contact authorized by the customer.

5.6 VPN

VPN options in panel 6.0. No key file is attached.
VPN options in panel 6.0. No key file is attached.
Reference Screen

Connection using OpenVPN

The VPN tab allows you to activate an OpenVPN connection by uploading a configuration file and, optionally, a key file. It should only be configured with files provided for that installation.

Field What to enter Caution
VPN connectionOn to activate the VPN; Off to keep it disabled.Do not activate VPN without confirming that the files and network are correct.
Configuration file (.conf)OpenVPN configuration file.Must correspond to the client's installation and VPN server.
Key file (.txt)Optional file with keys or credentials, if required by the deployment.It must be kept as sensitive information.
SaveApplies the selected settings.Then check that the device maintains access via the expected route.

Good practices. Always document the final IP, the adapter used for SIP, and any external services configured. Do not leave logs, SNMP, SMTP or VPN enabled if they are not part of the delivered installation.

6. Multimedia

The Multimedia section allows you to adjust audio, video, recordings, RTSP streaming and LCD screen. Some functions depend on the installed hardware, especially those related to the camera, video calling, recordings and display.

Call Audio Speaker volume, microphone sensitivity, echo cancellation, buffers and audio test.
Image and video Preview, brightness, contrast, saturation, hue, resolution and camera parameters.
Multimedia services Recordings, RTSP, voice prompt language and LCD screen messages when they exist.

6.1 Audio

Audio controls and sound test in panel 6.0.
Audio controls and sound test in panel 6.0.
Reference Screen

Levels, buffers, test and language

This screen adjusts the device’s audio. After changing settings, make a test call and check the speaker volume, microphone level and echo cancellation.

Field What to enter How to decide
SpeakerSpeaker output level.Set this during a real call. Turn up only enough to be heard clearly.
MicrophoneMicrophone pickup sensitivity.If the caller hears you too quietly, increase the value; If there is clipping or noise, reduce it.
Echo CancellationOn or off.It must be kept activated except for specific technical tests.
Audio BufferAudio buffer available in the dropdown.Affects stability and latency. Keep the setup value if the call works correctly.
Jitter BufferBuffer against network variations.It can help on unstable networks, but high values can increase the delay.
ToleranceLevel used for the audio test.Use the test to check remote audio without moving personnel to the panel.
Voice prompt languageLanguage or audio mode of the voice prompts.Select the language for audible messages or disable voice prompts/sounds if the installation requires it.

6.2 Video

Video image controls; preview is disabled in this capture.
Video image controls; preview is disabled in this capture.
Reference Screen

Preview and camera settings

The Video tab allows you to check the live image and adjust camera parameters. The capture includes a reference image in the preview box to clearly show where the camera feed appears.

Field What to enter When to adjust it
Live PreviewNot populated; shows the camera image.Used to check framing, visual focus and effect of settings.
BrightnessImage brightness level.Adjust this if the scene looks too dark or overexposed.
ContrastDifference between light and dark areas.Modify this if the image appears flat or has little detail.
SaturationColor intensity.Use moderate values to avoid artificial colors.
HueChromatic correction of the image.Do not change it unless the image has a color cast.
Resolution320x240, 640x480 or 800x600, depending on available selection.Higher resolution offers more detail; Lower resolution can reduce network consumption.
Auto White BalanceEnabled for the camera to adjust color temperature.This is recommended in most installations.
Color temperatureManual value if auto balance is not used.It should only be adjusted when working in manual mode.
Backlight compensationOff or On.Activate if there is strong light behind the person or object you want to see.
Line FrequencyOff, 50Hz or 60Hz.In European electrical installations, 50 Hz is usually used to reduce flickering.
Restore default valuesReturns video parameters to base values.Use this option if the adjustments leave the image incorrect and you need to start from scratch.

Note. Video settings are saved and auto-applied when moving a control, as indicated on the version 6.0 screen itself. Make small changes and check the preview before continuing.

6.3 Recordings

Recording screen with no available recordings.
Recording screen with no available recordings.
Reference Screen

Conservation and listing of recordings

Use this screen to choose how long recordings are kept and review the available recordings. The table is empty when there are no recordings.

Field What to enter Interpretation
Days to keep recordingsNumber of retention days. A value of 0 disables retention.Define it based on customer policy and available capacity.
Date/TimeData shown in existing recordings.Allows you to locate the time of the recorded event.
DestinationDestination associated with the recording.Helps identify call, access or related event.
TypeType of recording or event.Used to filter or understand the origin of the recording.
DurationRecorded time.It should be reviewed if calls or incidents are investigated.
ActionsOperations available on recording.It may vary depending on whether or not recordings are available.

6.4 RTSP Streaming

RTSP settings. The visible username and password have been concealed.
RTSP settings. The visible username and password have been concealed.
Reference Screen

RTSP video publishing

RTSP allows you to view the video from compatible systems. It should be configured only if the installation needs to integrate the camera feed into a viewer, recorder, or external platform.

Field What to enter Caution
RTSP StreamingOn to activate; Off to disable.The display indicates that RTSP is not available while the QR reader is active.
UserRTSP access user.Should be known only to authorized personnel.
PasswordRTSP access key.Change default values before delivering if the service remains active.
PortRTSP listening port.The value displayed on the screen is 554; change it only if the network requires it.

6.5 LCD

16×2 LCD controls.
16×2 LCD controls.
Reference Screen

Screen Messages

The LCD 16×2 tab lets you adjust the backlight, enter two lines of text and send or clear the displayed content.

Field What to enter What is it for?
BacklightSelect On, Off or (no change).Controls the backlight of the 16×2 LCD, if fitted.
Line 1First text to display.Use short, clear messages.
Line 2Second text to display.Used to complete the message without cluttering the screen.
SendApplies written text.Check the result on the physical screen of the device.
ClearClears the displayed content.Useful when you want to remove a temporary message.

Final check. After modifying audio, video, RTSP or LCD, make a test call and check image, sound, messages and external services before handing over the installation.

7. Relays and accesses

The Relays section allows you to define how the door-control outputs operate and how access is authorized using PIN, RFID cards, schedules, QR codes, logs, alarms and advanced options. These settings directly affect doors, locks, automations or auxiliary outputs.

Door-control outputs Relays 1, 2, 3 and combined action 1+2+3, with different activation modes.
Access credentials PIN, RFID and QR credentials can be assigned a name, code, schedule and door-control relay.
Control and traceability Schedules, logs, alarms and the external database help limit and audit access.

7.1 “Relays” tab

The “Relays” tab contains controls for the outputs available on the device. Options depend on the model and installed modules. Check which device each output controls before changing its settings.

Relays tab showing activation options for Relay 1, 2, 3, and combined.
Use this tab to choose the activation type for each available output.

Caution. Before saving changes, confirm which device each output controls. An incorrect setting could activate the wrong device.

7.2 PIN access

Use this tab to create PIN codes that open an output from the keypad. Each row can have a name, code, schedule and relay. The screen indicates a limit of 250 codes.

Relays PIN screen with empty fields.
The list shows ten rows per page. Each PIN can be linked to a name, schedule and relay.
Field What to enter Good practices
PositionRegistration number within the list.Used to organize and locate credentials.
NamePerson, home, service or use assigned to the PIN.Use clear names so you can audit access later.
CodePIN entered on the keypad.Choose a non-obvious code and share it only with authorized people.
ScheduleTime period when the PIN is valid.Select “24h” for access at any time, or choose another configured schedule.
RelayOutput activated when the PIN is accepted.Check that it corresponds to the correct door.
Previous / NextChanges the list page.Use these links to view other rows.
SaveSaves changes made to the list.Check the details before saving.

7.3 Access via RFID

Relays RFID screen with empty fields.
Manage RFID credentials with associated name, code, schedule and relay.
Reference Screen

RFID Cards

Use this tab to register RFID cards or credentials. For each card, enter a name, its code, a schedule and the relay to activate.

Field What to enter How to use it
NameUser, home, vehicle or assigned card.It must allow you to identify who the card belongs to.
CodeRFID code of the card or credential.Enter the exact identifier recognized by the system.
ScheduleCard validity schedule.Useful for maintenance staff, suppliers or users with limited access hours.
RelayOutput that will be activated with that card.Select the corresponding door or maneuver.
SaveApplies changes to the current page.Save after adding or deleting entries, or changing relay or schedule assignments.

7.4 Access times

Access schedule editor by time and weekdays.
Set time periods and permitted days.
Reference Screen

Time zones

Schedules limit when PIN codes, RFID cards and, if available, QR codes can be used. To delete a schedule, the screen instructs you to leave its name blank.

Field What to enter Usage example
ScheduleName of the time slot.For example: Working hours, Maintenance, Deliveries, 24h.
Start / EndValidity start and end time.Use clear time format and verify that the system time is correct.
L M X J V S DDays of the week when applicable.Check only authorized days.
Blank nameDelete the schedule as indicated on the screen.Before deleting a schedule, check that no active PIN, RFID or QR credentials use it.

7.5 Access via QR

Relays QR tab to generate access codes.
QR access list and button to generate a new code.
Reference Screen

QR code generation

Allows you to generate QR codes linked to an operating period and an opening relay. It is useful for temporary access when the device has a compatible reader/camera.

Reference Screen

Configuration of the generated QR

When you press Generate QR, the interface allows you to define name, validity period, time, relay and mailing. This screen completes the configuration of temporary access by QR.

Field What to enter Caution
NameIdentification of the generated QR.Use a name that indicates user, visit, service or purpose.
RelayOutput activated by the QR code.Check that it matches the authorized door.
ScheduleSchedule associated with the QR, if applicable.Useful to limit usage by days and hours.
Start / EndCode validity period.Define expiration dates/times when access is temporary.
TemporaryQuick QR duration, for example one hour when that value is selected.Use this option for short, controlled accesses.
Date rangeStart and end date and time.Use this option when the QR must be valid for a specific interval.
Send by mail toRecipient's email address.Requires SMTP configured and should be used only with authorization from the person responsible.
Generate QRCreate the code for use.Do not hand out QR codes without registering who they are valid for and when they expire.

7.6 Access logs

Relays logs tab with no records visible.
Access log and export controls. No records appear in this capture.
Reference Screen

Query, export and delete

The logs show access records and related events. The screen allows exporting in spreadsheet formats and deleting records when appropriate.

Field What it shows Recommended use
DateTime of registration.Required to audit incidents.
TypeType of event recorded.Helps distinguish PIN, RFID, QR or other accesses.
Name/CodeIdentification associated with the access.Allows you to relate the event to a credential.
Position / Schedule / RelayConfiguration data used in access.Useful for checking why an output was activated.
ExportDownload records, according to available icons.Use export before deleting records if evidence needs to be retained.
Delete logsDelete records based on the selected option.Do not delete logs without authorization from the person responsible for the installation.

7.7 Alarms

External alarm settings for push button or keypad.
External alarm options. The email address is an interface example.
Reference Screen

External alarm due to sensor change

Allows you to send an email notification if the sensor status changes during the set time. The screen allows you to indicate whether the model uses a button or keypad.

Field What to enter Precondition
External alarmOn to activate; Off to disable.Activate only if sensor change warning is needed.
ModelPushbutton or Keypad.Must match the front/installed equipment.
TimeMonitoring time in seconds.Defines how long the state change is evaluated.
Notice emailAddress that will receive the notification.SMTP must be configured correctly in Connectivity.

7.8 Advanced Options

Advanced Relays settings; database connection values are concealed.
Cloud and external database settings. IP, database name, username, password and SQL query are concealed.
Reference Screen

Cloud and external database

This tab configures Cloud and an external database connection. Use these options only when the technical lead has specified the integration.

Field What to enter Caution
Use CLOUDOn or Off depending on the integration contracted.Do not activate Cloud if it is not part of the project.
External DBOn if an external database is queried.Requires client-validated server, credentials, and query.
DB server IPDatabase server address.It must be accessible from the device's network.
DatabaseName of the database.Must match the server configuration exactly.
User / PasswordDatabase access credentials.These are sensitive data and must be safeguarded.
SQL QUERYSQL query to be executed.It must be provided and validated by authorized technical personnel.

Delivery to customer. Document which relays each credential activates, what hours are active, and who is authorized. Do not provide PINs, cards, QR, database credentials or Cloud configuration without approval from the person responsible for the installation.

8. Keypad / Pushbutton

The Keypad / Pushbutton section defines how the keypad, pushbuttons, status LED and auxiliary inputs behave. These settings determine whether the user dials extensions, enters PINs, calls contacts, activates relays, or uses external inputs.

Front mode Keypad, pushbutton, auxiliary inputs, handset or combinations depending on the installed equipment.
Dialing Digit length, default mode, calls by extension, by IP or key actions.
Signaling Status LEDs, auxiliary inputs and button holding behavior.

8.1 General settings

General keypad/push-button configuration: type, digit length and default dialling.
General settings for the keypad/push-button panel.
Reference Screen

Device type and default dialing

Allows you to select the front panel operating mode and define how the device interprets the digits entered by the user. In the drawing below, each button or number opens the individual settings for that key.

Field Options/value Correct use
Choose type
Keypad / push buttonAuxiliary InputsKeypad + relay pushbuttonHandsetHandset + keypad
Must match the front and installed accessories. Do not select hardware features that your device does not have.
Keypad / push buttonMixed mode for keypad and push button.Use when the device has a keypad and call/open button according to configuration.
Auxiliary InputsGives prominence to the auxiliary inputs.Use if calls or relays are to be triggered from external contacts.
Keypad + relay pushbuttonCombines keypad with push button associated with relay.Use if the button must act on a relay output.
Handset / Handset + keypadModes for devices with handsets.It should only be selected on models that have a handset.
Manual dialing digit lengthNumber of digits that make up a manually dialed extension.Must match the installation extension length.
Access PIN lengthNumber of digits expected for access PIN.It must match the length of the codes defined in Relays and accesses.
Default dialing
Extension DialingPIN dialingAPI dialing
Defines what the device interprets when the user enters digits.
Extension DialingThe digits are treated as extension to call.Use in installations where the visitor directly dials an extension.
PIN dialingThe digits are treated as a password.Use when the keypad is primarily used for code opening.
API dialingDigits are sent or interpreted using API integration.Use only if an external integration is defined.
Drawing of buttons and numbersThe push-button icon and each keypad digit open their respective configuration screens.Set each button or key to be used after selecting general mode.

8.2 Button or key configuration

Reference Screen

Action assigned to a button or number

This screen appears when you click on a button or number in the general configuration drawing. Allows you to define what that specific key does. Some options require filling out the extension call block or the direct IP call block.

Configuration of a key or push button and its actions.
Configuring the action assigned to a key or push button.
Selectable value What does it do? Required fields
Choose type
Simple KeyEnd callCall prefixPIN prefixExtension callDirect call to IPManual response
Select the action that key or button should perform.
Simple KeyThe key remains a simple system action.No additional call data required.
Cancel dialing in progress, End callCancel dialing or end a call.No destination required.
Call prefixEnter a call prefix.Should be used only if the facility dialing requires it.
PIN prefixEnter a password/PIN prefix.Must match the defined access criteria.
Extension CallCall a PBX extension.Fill User/Ext. and select SIP Account 1 to 5.
Direct call to IPCall an IP or server directly.Fill IP, User/Ext. and SIP Account 1 to 5.
Manual Answer on Incoming CallAllows you to use the key to manually answer incoming calls.Use when the installation requires manual response from the device.
SIP account
SIP account 1SIP account 2SIP account 3SIP account 4SIP account 5
Select a configured and operational account in the SIP Accounts section.
SIP account 1 to 5Each option indicates which SIP account that key will use to call.If the chosen account is not registered, the key will not be able to complete the call.

8.3 Push button contacts

Reference Screen

Progressive push call

Open this screen using the call-button icon in the diagram. Defines the order of contacts that the device will call. If there is no response within the indicated time, it moves to the next configured contact.

Screen for ordering progressive-call contacts.
Progressive-call contacts and the wait time before moving to the next destination.
Field What to enter How to decide
TimeoutSeconds before moving on to the next contact. A range of 3 to 99 seconds is supported in the interface.Use enough time so that the destination can respond without delaying the sequential call too much.
Contact 1 to 4Call order. Contact 1 is attempted first; If there is no response, continue with the next configured one.Sort destinations by priority: reception, concierge, maintenance, etc.
NameDescriptive label for the contact.Use clear names for maintenance and later review.
User / Ext.Destination extension or user.It must match the configured PBX or destination.
IP / ServerDestination server or IP.Use the corresponding SIP server or IP address.
PortSIP port of the destination.5060 is common, but the actual installation configuration must be respected.
Allow press to hang upActivated if one press ends the call.Use if you want the user to be able to end the call from the button.
Press delay
Disabled0.5s1s1.5s2s3s
Defines how long the button must be held down before executing the action; Higher values prevent accidental keystrokes.

8.4 LED Configuration

LED tab with settings for the device operating states.
Device states and visual patterns that can be assigned to the LED.
Reference Screen

Visual status indication

Allows you to define how the LED behaves according to the device status: standby, successful registration, outgoing call, incoming call and active communication.

LED option What does it do? When to use it
Configurable statesIdle, Registration OK, Making call, Incoming call and In communication.Assign behavior that is consistent and easy to recognize for the end user.
Available options
OffOnNormal flashingFast flashingSlow flashing
The same list can be chosen for each state.
OffThe LED remains unlit in this state.Use if no visual indication is desired.
OnThe LED remains steadily lit.Useful to indicate idle, successful registration, or stable status.
Normal flashingIntermediate flashing.Useful for indicating active communication without being too flashy.
Fast flashingMore visible flickering.Useful for outgoing or incoming calls, when you want to attract attention.
Slow flashingSoft flashing.Can be used for lower priority informational states.

8.5 Auxiliary inputs

Configuration of four auxiliary inputs, SIP account, destination and relay.
Assign a SIP account, destination and relay to each auxiliary input.
Reference Screen

Actions from external contacts

Allows you to configure up to four auxiliary inputs. Each input works as an external trigger: you can initiate a call from a SIP account, send the call to a specific destination and, if applicable, activate a relay.

Auxiliary input Identifies which of the four physical inputs is being configured.
Associated call SIP account and destination define where you call from and who you call.
Relay output Allows you not to activate anything or to maneuver a specific output.
Item Options/value Correct use
InputInput 1, 2, 3 or 4.Identifies the physical contact being configured. It must match the actual wiring of the installation.
SIP account
SIP account 1SIP account 2SIP account 3SIP account 4SIP account 5
Select the account from which the call associated with the input will be made.
DestinationConfigured extension, user or destination.Must match the destination that should receive the call or action.
Relay
NoneRelay 1Relay 2Relay 3Combined 1+2+3
Use None if the input should not open or activate output; Select relay only if you must operate an output.
NoneThe auxiliary input does not activate any relay.Use when the input should only generate a call or notification.
Relay 1 / 2 / 3Activates a specific output of the equipment.It must match the door, lock or control wired to that relay.
Combined 1+2+3Activates the three relays together.Use only if the installation requires a documented simultaneous maneuver.

Check. After changing the type of keypad, LED, auxiliary inputs or pushbuttons, physically test each key and each input to confirm that it calls the correct destination and does not activate unintended relays.

9. Modules and licenses

Modules and licenses panel showing On/Off status and Activate controls.
Modules and licenses panel showing On/Off status and Activate controls.

The Modules and Licenses section allows you to activate or deactivate functions available on the device. These parameters must match the installed hardware, available licenses, and actual installation usage.

Reference Screen

Modules loaded

The 6.0 device reviewed lists API, Modbus, video, RFID, RS485, QR and SNMP. Each disabled module has an “Activate” button, while On cannot be selected directly. Activation may require a licence or supplier assistance; confirm the service conditions before using “Activate”. Enabling a feature does not replace the required hardware or configuration.

Module What it enables When should it be active
APIAllows you to use integrations or external calls to device functions.Enable only if the installation uses documented API integration.
ModbusEnables communication with Modbus compatible systems.Use On if the equipment is part of an industrial or control integration that requires it.
VideoActivate functions related to camera, preview, video call or video services.It must be active when the equipment has a camera or the installation uses video.
RFIDEnables RFID card and reader functions.Activate only on devices with an RFID reader installed and card access configured.
RS485Enables communication via RS485 bus.Use On when there is an RS485 connection in the installation.
QREnables QR code access features.Must be active if QR codes are to be generated and read.
SNMPEnables SNMP monitoring functions.Activate only if the client has an SNMP platform and it is configured in Connectivity.

Important. If a feature is not used, it should remain disabled. Before handing over the installation, verify that only the required modules remain active and that each active function has been tested.

10. Tools

On the 6.0 device reviewed, Tools includes test calls, restart, firmware updates, web server, API and Cloud. These settings can affect remote access, communication or the overall operation of the device.

Testing and reboot Allows you to launch test calls, restart the device and schedule automatic restart.
Maintenance Check firmware version, update server and manual update.
Access and integration Controls HTTPS, the web port, API and Cloud.

10.1 General settings

Tools: test call, restart and reset options.
Tools: test call, restart and reset options.
Reference Screen

Test call and reboot

Allows you to check a call from the web interface and perform equipment maintenance actions. It should not be used to restore factory settings unless expressly authorized.

Field/action Options/value Correct use
Test callAllows you to start a call from the device to check communication.Use this test after configuring SIP, network, or call destinations.
Choose type
Extension Call (PBX)Direct call to IP
PBX calls a PBX extension. Direct to IP also shows the IP field and is used for point-to-point calling.
User / Ext.Extension, SIP user or test destination.Must exist on the PBX or the indicated IP destination.
Reboot DeviceRestart the device keeping the settings.Useful after changes that require a restart or to recover a blocked service.
Restore DeviceRestore factory settings.Critical Action: Clear configurations. Use only with permission and prior copy of necessary data.
Automatic Restart
OffEvery 12 hours.DailyWeeklyMonthly
Schedule reboots only if the installation requires it. In normal use it may remain off.
OffDoes not schedule automatic restarts.Recommended option if there is no specific need for preventive maintenance.
Every 12 hours.Restart your device twice a day.Use only in installations where this policy has been expressly defined.
DailyPerforms an automatic restart per day.Can be used in installations with scheduled maintenance.
Weekly / MonthlyReduces the frequency of automatic reboot.Select the periodicity indicated by the technical manager.

10.2 Updates

Reference Screen

Firmware and update server

Shows the installed version, update status, update server, and the option to manually upload a firmware file.

Tools > Updates screen; the server URL and firmware file are concealed.
Firmware version and status, update server and manual update option. The URL and file are concealed.
Field What it indicates Correct use
Current versionFirmware installed on the device. The device reviewed shows “CSIP H6 — V 6.0”; 6.0 is the firmware version, not the processor version.Used to identify the version before support, maintenance or update.
StatusIndicates whether the firmware is updated based on the configured server.Review this field before manually uploading firmware.
Server URLServer from which the device checks for updates.Do not change the URL unless instructed by support or the technical manager.
Manual updateAllows you to select a compatible firmware file.Use only correct files for the model and version. Maintain stable power and network during the process.

Caution. An interrupted update may make the device inaccessible. Before updating, please confirm model, file version, stable power and maintenance window.

10.3 Web server

V6.0 web server with HTTPS and access port settings.
HTTPS and web server port settings for the V6.0 panel.
Reference Screen

Web access to the device

Allows you to activate HTTPS and change the access port to the web panel. Any changes to this screen may change the address from which the equipment is accessed.

Field Options/value Correct use
HTTPS
ActivatedDisabled
Enabled forces encrypted access if the installation supports it. Disabled maintains normal HTTP access.
PortTCP port of the web server. The device reviewed showed 8090.If changed, access starts using the new address with that port. Example: http://IP:port/.
Save changesApplies web settings.Before saving, confirm that you know the new IP and port so you don't lose access to the panel.

10.4 API

Reference Screen

External integration via API

The 6.0 panel reviewed shows API status, token/API key, IP allowlist, security level and notification URL. The API was disabled on that device; the behaviour of every control when enabled has not been verified.

Field Options/value Correct use
APIIndicates whether the API is active.Depends on the corresponding module/license. If external integration is not used, it must remain disabled.
Token / API KeyKey that authorizes requests to the API.Sensitive data. It should not be shared in screenshots, emails or public documentation.
IP allowlistOne IP per line.Limits which addresses can use the API. Recommended when the IP of the external system is known.
Security level
Token/API KeyIPToken + IP
Token + IP is the most restrictive option when the integration allows it.
Token/API KeyThe request must include the configured key.Useful when you cannot limit by IP or when the IP of the external system changes.
IPAuthorization is based on the allowlisted IP.Use only if authorized IPs are fixed and known.
Token + IPRequires valid key and allowlisted origin.It is the most secure option when the external system has a fixed IP.
Notifications URLExternal address that will receive notices or events.Must be a valid URL maintained by the receiving system.

Security. The API should only be active if a documented integration exists. Protect the token, limit IPs when possible, and test the integration before delivering the installation.

10.5 Cloud

Configuration reference

Remote access through Cloud

The Cloud tab shows service status, a link to cloud.panphone.es and a “Use cloud services” option. The Connected status in the screenshot applies only to that device; check the status of your own device.

ItemWhat it showsCorrect use
StatusService connection indicator.Check the status on the device itself; the presence of the tab alone does not mean that the connection is operational.
Use cloud servicesEnable checkbox and “Save changes” button.Enable it only if the installation has the service and remote access is authorised.
cloud.panphone.esLink displayed by the interface.Access to the portal may require an account or permissions separate from those used for the device.

Scope. The interface shows a Cloud option in Tools and a separate “Use CLOUD” option in the advanced Relay settings. It was not verified whether they share a service or internal configuration; check their purpose before enabling them.

Remote access. When Cloud service is available for the installation, the device panel can be opened remotely. Its own credentials are needed to enter the panel; keep this device's individual recovery credential even after changing the day-to-day password. Portal access and device-panel access are separate steps.

11. Users

The Users section allows you to change the access password to the web panel, select the interface language and close the administration session. It is the last section of the configuration side panel.

Reference Screen

User, language and logout

Access to the web panel is managed from this screen. The key must be guarded and changed during startup if a default key is maintained or known to multiple people.

Field/action What to enter Correct use
UserCurrent web panel user.Identifies the account under which the device is managed.
New PasswordNew panel access password.The 6.0 panel requires at least 8 characters, including an uppercase letter, a lowercase letter, a number and a symbol. Store it using the authorised procedure.
Repeat New PasswordRepetition of the new password.Must match the previous field exactly to avoid errors when saving.
SaveSave the password change.After saving, document the new key in the authorized internal procedure, not in the customer manual.
Language
EnglishPortugueseSpanishBasqueCatalan
Change the language of the web interface. This setting does not necessarily change the audio voice prompt language, which is configured in Multimedia.
ChangeApplies the selected language.Use the language required by the installer or maintenance person.
Sign outClose the administration session safely.Should be used when finishing setup, especially on shared computers or client networks.

Delivery. Do not include real passwords in screenshots, reports or delivered documentation. Upon completion of commissioning, log out and ensure that access is protected.

11.1 System date and time

The board incorporates a specific date and time setting screen. This setting is important because it affects access schedules, event logs, logs, time codes, and maintenance checks.

Field/action What to enter Correct use
System date and timeShows the current date and time of the board.Should be reviewed before activating schedules, registrations or temporary access.
Date type
AutomaticManual
Automatic synchronizes with NTP server. Manual allows you to enter date and time from the panel.
AutomaticThe board takes the time from an NTP server.Recommended when the device has a network output to the configured server.
ManualThe installer sets the date and time directly.Use this mode if there is no NTP access or during an isolated startup.
NTP ServerTime server, for example pool.ntp.org.It must be accessible from the network configured on the board.
Time zoneInstallation time zone.For mainland Spain, select Europe/Madrid.
Manual date/timeDate and time entered by the installer.Only applies when the date type is Manual.
SaveApplies the time settings.After saving, verify that the time is correct in Home and in the logs.

Review. If events appear with incorrect times or access times do not act when they should, first check time zone, date mode and NTP server.

12. OPTO additional board

The OPTO add-on board is an optional accessory for installations requiring auxiliary inputs and an additional relay output. This section should only be applied when the OPTO board is physically installed in the equipment.

Inputs 1-4 They allow wiring external contact signals.
Input power The inputs can use internal or external power, as selected by JP1 and JP2.
Relay 3 Provides an additional output with voltage-free contacts.

12.1 Identification of terminals and jumpers

Physical reference

OPTO board, inputs and relay 3

The table identifies the auxiliary inputs, ground, reference positive, relay 3 contacts and jumpers JP1/JP2. The selection of internal or external power must be decided before wiring the inputs.

Terminal / element Indicated function Correct use
1 to 4Input 1, Input 2, Input 3 and Input 4.Connect the external contacts that must be detected by the board here.
5GND.Ground reference for input wiring according to the diagram used.
6+V.Positive input power reference.
7 and 8Relay 3 contacts.Voltage-free output for the additional maneuver defined in the installation.
JP1 and JP2Power selection jumpers.Connected: internal power. Disconnected: external power.
NO/NC jumperRelay output selection as normally open or normally closed.It must be adjusted to the type of lock, barrier or automation connected.

12.2 Input power supply

The OPTO board supports two ways to power the inputs. The choice depends on the type of signal available in the installation and must respect the connection diagrams of the board.

Mode Status of JP1 and JP2 Indicated power
Internal powerJP1 and JP2 connected.5V (+V). Confirm this mode against the supplied board's wiring diagram.
External powerJP1 and JP2 disconnected.5-24V and GND. Confirm this mode against the supplied board's wiring diagram.

Caution. Do not mix internal and external power in the same configuration without checking the electrical schematic. With the equipment powered, no jumpers or terminals should be manipulated.

12.3 OPTO wiring check

Before proceeding to the equipment configuration, check that the physical wiring of the OPTO board matches the installation diagram. This point does not replace the configuration of auxiliary inputs in the Keypad / Pushbutton section; It only confirms that the additional board is connected correctly.

Check What to check Expected result
Inputs 1-4Each external contact must go to the intended input terminal.The physical input matches the installation layout.
GND and +VThe power reference must correspond to the chosen mode.Do not combine internal and external power.
JP1 and JP2Check if they are connected or disconnected according to the scheme used.JP1/JP2 connected for internal power; disconnected for external power.
Relay 3Terminals 7 and 8 must only go to the planned maneuver.Relay 3 is not used if it is not wired and documented.
NO/NCCheck the position of the relay output jumper.The contact remains normally open or normally closed depending on the lock or automation.

12.4 OPTO Functional Test

  1. Verify that the OPTO board is installed and that the equipment is de-energized before handling it.
  2. Check if JP1 and JP2 should be connected or disconnected according to the chosen power mode.
  3. Check that each physical input corresponds to the function intended in the project.
  4. Test each input individually and confirm that it calls the correct destination or activates the intended maneuver.
  5. Test relay 3 only if it is wired and part of the installation.

Delivery to customer. Document which OPTO input has been used, which physical contact activates it, whether it works with internal or external power and which relay or destination is associated.

13. Mounting accessories

This section includes dimensional assembly references for the indicated series. The dimensions should be used as an installation guide and physically verified before drilling, machining or preparing the recess opening.

C Series Reference drawing of the gray rear cover.
Series 4 surface Back cover reference for surface mounting.
Series 4 recessed Frame reference for recessed installation.

13.1 C Series, gray rear

Assembly drawing

C Series back cover

Use this reference to locate the fixing points and check the available space before installing the equipment on the intended surface.

13.2 Surface Series 4

Assembly drawing

Surface Series 4 back cover

The surface back cover is used when the equipment is fixed directly on a wall or stand. Check the dimensions of the fixing points and cable outlets before marking.

13.3 Series 4 for recessing

Assembly drawing

Series 4 frame for recessing

The recessed frame requires preparing the hole and checking depth, cable passage and fixings before placing the front of the intercom.

Before installing. Always check the physical model supplied, the type of box, the orientation of the front and the cable passage. Do not drill or machine until you confirm that the dimensions correspond to the installed accessory.

14. Technical data

This section contains the PANPHONE IP CSIP V6 technical specifications. The hardware information is based on the CSIP V6 board specifications; software features were checked against the firmware 6.0 screens examined.

Model and version. CSIP V6 identifies the product family; “CSIP H6 — V 6.0” is the string shown by the device reviewed. In this manual, 6.0 refers to firmware. That string alone does not confirm the processor model or the physical board revision.

14.1 Communication and buttons

Feature Technical data Observation
Communication protocolSIP 2.0 compliant with RFC 3261.Allows you to register the device in an IP PBX or make direct calls over IP according to configuration.
Buttons / keypadA call key or 12-key keypad: 0-9, # and *.Depends on the front installed. The configuration is done in Keypad / Pushbutton.

14.2 Audio

Feature Technical data Observation
Microphone1 electret.Sensitivity is adjusted from Multimedia > Audio.
Speaker2 W, 8 ohms.Volume is adjusted from Multimedia > Audio.
Audio improvementsEcho cancellation and ambient noise reduction.Helps improve hands-free conversation in noisy environments.
Audio ModeFull duplex.Allows you to talk and listen simultaneously during communication.
Sound pressure77.5 dB at 1 kHz / 1 m.Speaker reference value.
Audio codecsG.711a/u, G.722, G.726-32, G.729, GSM and OPUS.Codec priority is configured on each SIP account.

14.3 Electrical properties, consumption and network

Feature Technical data Observation
External power12 Vdc +/- 15%, 2 A.Recommended power supply for continuous use.
PoE PowerPoE IEEE 802.3af (Class 0, 12.95 W max).Allows you to power the equipment directly through the RJ45 network cable.
Consumption at rest100 mA (~1.2 W at 12 Vdc).Equipment waiting, registered and in service.
Call consumptionMaximum 350 mA (~4.2 W at 12 Vdc).During active conversation with standard speaker.
Consumption with amplifier 10 WUp to 1 A (~12 W peak at 12 Vdc).In versions equipped with a 10 W amplifier stage at maximum volume.
LAN interfaceRJ45, 10/100 Base-TX with Auto MDI-X.Direct connection to local Ethernet network.
Relay contacts2 NC/NO relays, max. 24 V / 2 A DC, 120 V / 2 A AC.Voltage-free contacts. Optional third relay via OPTO board.

14.4 Supported protocols

Protocol/service Availability Usage
SIP 2.0Supported.SIP registration and calls.
UDP / TCPSupported.Communications transport according to configuration.
RTSPSupported on devices with video.Camera streaming with user, password and port.
HTTP / HTTPSInternal web server; HTTPS configurable in Webserver.Authorized local or remote access to the configuration panel.
MODBUSAvailable as a module/license.Integration with external systems or SCADA.
RS485Available as a module/license.Serial communication in compatible installations.
SNMPAvailable as a module/license.Supervision and sending of traps.
DHCPSupported.Automatic IP assignment.
NTPSupported.Automatic date and time synchronization.

14.5 Dimensions and mechanical characteristics

Item/Feature Dimensions / Data Observation
Surface Series 4 dimensions185 x 105 x 31mmWall mount with back cover included.
Dimensions Series 4 for recessing216 x 128 x 8mm (Front)
Embedded hole: 182 x 92 x 30mm
Built-in wall installation with recessed box or frame.
C Series Dimensions (Front)175 x 100 x 30mm approx.Frontal format for mounting on columns or specific supports.
CSBOX format dimensions125 x 93 x 52 (or 42) mmClosed plastic or aluminum metal box.
CSIP electronic board dimensions100 x 85mmDimensions of the main board without casing.
OPTO auxiliary board dimensions42 x 42mmOptional expansion card.
Operating temperature-10 ºC to +55 ºC.Suitable for indoor and outdoor installations depending on the enclosure.
Relative humidity10% to 95%, no condensation.Supported environmental range.

14.6 Special Features

Feature Availability Observation
Remote opening by dial codeYes.Allows you to open from an authorized extension or external telephone.
Voice messagesYes.Messages such as open door or making a call; They can be customized and configured in different languages.
Integrated relays2 independent relays.Voltage-free contacts configurable as NC or NO.
Input for push button or external sensor1.Input available on the motherboard depending on model and wiring.
Wiegand Mifare Port1.For compatible proximity or biometric sensors.
LED indicators1.Waiting, call and communication indication according to configuration.
OPTO Expansion CardOptionally available.Adds 4 auxiliary inputs and an output relay.
DHCP Automatic IP AssignmentYes.Configurable from Connectivity.
Traffic log controlYes.Allows you to review logs from the panel.
Local and remote configuration via webYes.Access through the device's internal web server.
I/O event notification per SIP callYes.Allows notifications per SIP call depending on inputs and configuration.
Integration via APIOptionally available.The 6.0 interface examined shows API status, token, IP allowlist, security level and notification URL.
MODBUS protocolYes.Oriented towards integration with SCADA or external systems.
RTSP StreamingYes, on devices with video.Configurable with user, password and port. The interface indicates that it is not available while the QR reader is active.

15. Frequently asked questions

This section includes common installation, start-up and maintenance questions. The answers are designed to help you check the equipment without modifying parameters unnecessarily.

Question Answer Recommended check
I can't access the web panel. What do I check first?Check that the device is powered, that the network cable is connected, and that the computer is on the same network as the device.If the IP is unknown, consult the technical owner and section 2.9 before changing the board.
Can I power the device through PoE and an external power supply at the same time?The equipment supports PoE or external power, but the installation must follow the scheme defined by the technician.Before connecting, check the power section and confirm if PoE or a 12 V DC power supply will be used.
The SIP account does not register. What should I check?This is usually due to an incorrect user, password, server, port, transport, or network.Review SIP Accounts and confirm connectivity with the PBX. Also check DNS, gateway and network adapter for SIP.
The call connects, but the audio is poor. What should I adjust?Check speaker volume, microphone sensitivity, echo cancellation, audio buffer and jitter buffer.Use Multimedia > Audio and make a test call before delivering the installation.
The relay does not open the door. Where do I start?Check that the correct relay is being activated and that the NO/NC contact matches the type of lock or automation.Check Relays, the terminal diagram and the position of the NO/NC jumpers.
When should I use the OPTO board?Only when the installation needs additional auxiliary inputs or the third relay.Physically verify that the OPTO board is installed and that JP1/JP2 are in the correct position for input power.
Why doesn't WiFi or 4G/LTE appear operational?Because those functions depend on the installed hardware and the corresponding configuration.Check Modules and Licenses, and check Connectivity > WiFi or Connectivity > 4G/LTE.
Can I use RTSP and QR at the same time?The interface indicates that RTSP is not available while the QR reader is active.Define in the project whether QR reading or RTSP streaming is prioritized.
What do I do if the schedules or logs appear with the wrong time?The system date and time should be reviewed.Set NTP, time zone or manual setting on the Date/Time screen.
When should you activate the API?Only when there is a documented external integration.Configure token/API Key, IP allowlist, security level and notification URL. Do not share the token in public documentation.
What should I check before handing over the installation?Network, SIP, audio, relay opening, PIN/RFID/QR access, active modules, date/time, credentials and logout.Leave only the features actually installed and tested documented.

16. Contact and support

Back to home

Requesting assistance

For installation, configuration or maintenance assistance, contact your supplier or technical support using the official channels supplied with the device. Include the model, firmware version and a description of the issue.

Do not send passwords, tokens, private keys or screenshots containing installation data through public channels.

Tap outside the image or use the close button to return to the manual.